Crowcon Xgard Type 1 Intrinsically Safe Toxic and Oxygen Detector

  • Crowcon Xgard Type 1 Intrinsically Safe Toxic and Oxygen Detector
  • Crowcon Xgard Type 1 Intrinsically Safe Toxic and Oxygen Detector
  • Crowcon Xgard Type 1 Intrinsically Safe Toxic and Oxygen Detector
  • Crowcon Xgard Type 1 Intrinsically Safe Toxic and Oxygen Detector

Item #
XXYY-Xgard-Type-1
Price
$678.00
Xgard Type 1 Intrinsically Safe Toxic and Oxygen Detector
Xgard Junction Box Options
Quantity
Send Page to Friend

Xgard Type 1 Intrinsically Safe Toxic and Oxygen Detector by Crowcon

The Xgard range of gas detectors has been specifically designed to meet your requirements. The dangers presented by toxic and flammable gases as well as oxygen deficiency vary with each application.

Xgard offers three different sensor concepts so you can choose exactly what you need for your site. Xgard is available in flameproof, intrinsically safe, or safe area formats for use in all environments, whatever the classification.

Low cost of ownership

  • Designed for easy installation and maintenance - keeps costs down
  • Three junction box options - designed to make replacement of sensors and sinters extremely simple. Spare sensors simply plug-in
  • Many spare parts are common to all Xgard models - keeps spares holding requirements to a minimum

Flexible installation options

  • Designed for either wall or ceiling mounting - no need for additional brackets
  • Can accommodate M20, 1/2" NPT or 3/4" NPT cable glands - suits all site requirements
  • High temperature models are available for hot environments (up to 150°c)
  • Accessories are available for duct mounting and sampling applications as well as remote gassing - simple sensor checking

Wide range of sensors

  • Poison resistant pellistors, for all flammable detection needs including hydrocarbons, hydrogen, ammonia, jet fuel, leaded petrol and vapours containing halogens
  • Electrochemical sensors are used to detect a vast range of toxic gases and oxygen
  • Thermal conductivity sensors are available to monitor % volume concentrations of gases

Rugged and reliable

  • Manufactured using a choice of three materials: glass reinforced nylon, highly durable aluminium with a tough polyester coating, or 316 stainless steel for ultimate corrosion resistance - designed to operate even in the harshest environments
  • Spray deflectors and weatherproof caps are available for use in areas subject to regular wash-downs, or offshore environments
  • All models have been validated to the functional safety standard IEC 61508 (SIL 1 to SIL 3)



 
Type 1
Type 2
Type 3
Type 4
Type 5
Type 6
Size
156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
195 x 166 x 111mm (7.6 x 6.5 x 4.3 inches)
156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight
Nylon: 0.5 kg
Alloy: 1kg (2.2lbs)
316 S/S: 3.1kg (6.8lbs)
Aluminium: 1kg (2.2lbs)
Stainless steel: 3.1kg (6.8lbs)
1.5 kg (3.3lbs)
Aluminium: 1kg (2.2lbs)
Stainless steel: 3.1kg (6.8lbs)
Enclosure material
ATEX certified: Glass reinforced nylon or 316 S/SUL Certified: Aluminium or 316 S/S
Aluminium or 316 Stainless Steel
Aluminium
Aluminium or 316 Stainless Steel
Ingress protection
IP65
IP54
IP65
Cable entries
1 x M20, 1/2 "NPT or 3/4 NPT* on right-side
Terminations
0.5 to 2.5mm2
Sensor type
Electrochemical
Catalytic bead
316 S/S sensor housing with catalytic beads
Catalytic bead
Thermal conductivity
Operating temperature
-40 to +50 °C
(-40 to 122 °F)
(sensor dependant)
-20 to +50°C
(-4 to 122°F)
-40 to +80°C
(-40 to 176°F)
-20 to +150°C
(-4 to 302°F)
-40 to +55°C
(-40 to 131°F)
+10 to +55°C
(50 to 301°F)
Humidity
10 to 95% RH non-condensing
0-99% RH non-condensing
0-90% RH
Repeatability Zero drift
<2% FSD (Typical)<2% FSD per Month (Typical)
Response time
T90 <15s OxygenT90 <30s to 120s Toxic(sensor dependant)
T90 <15s (Typical)
Operating voltage
8-30V dc
2.0V dc +/- 0.1V (Typical)
10-30V dc
Power requirements
24mA maximum
300mA (Typical)
50mA at 24V dc 1.2W
Electrical output
2- wire 4-20mA (current sink)
3- wire mV bridgeTypical signal: 12-15mV/ %LEL CH4
3- wire mV bridgeTypical signal: >10mV/%LEL CH4
3- wire 4-20mA (current sink or source)
Approvals
ATEX: II 1 G
Exia IIC T4 Ga (Tamb -40 to +55°C)
UL/cUL: Class I, Div. 1
Groups A, B, C, D
IECEx
GOST-R
ATEX: II 2GD
Exd IIC T6 Gb (Tamb -40 to +50°C)
UL: Class I, Div. 1
Groups B, C, D
IECEx
GOST-R
ATEX: II 2 GD
Exd IIC T4 Gb (Tamb -40 to +80°C)
Exd IIC T6 Gb (Tamb -40 to +50°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1 
Groups B, C, D
IECEx
GOST-R
ATEX: II 2 GDExd IIC T3 Gb (Tamb -40 to +150°C)
ATEX: II 2 GDExd IIC T6 Gb (Tamb -40 to +50°C)
Exd IIC T4 Gb (Tamb -40 to +80°C)
Ex tb IIIC
T180°C Db
UL: Class I, Div. 1
Groups B, C, D
IECEx
GOST-R
EMC compliance
EN 50270 FCC Part 15 ICES- 003
*3/4" cable entry only available on aluminium juntion boxes.