IRmax Infrared Hydrocarbon Gas Detector by Crowcon
IRmax is a compact, low power and highly rugged infrared (IR) gas detector, that delivers rapid, fail-safe detection of methane, butane, propane and many other hydrocarbon gases and vapours. The IRmax infrared gas detection system offers the choice of a detector only, a local gas/status display, a remote gas/status display or non-intrusive calibration via an I.S. calibration tool or hand-held HART communicator.
Dependability in all conditions is what makes the IRmax stand out from the crowd, with the reliability of the IRmax hydrocarbon detector proven in hot, cold, wet and saline environments.
IRmax's unique Stay-ClIR optical components are treated with a highly durable coating that completely prevents faults due to condensation, making it ideal for offshore use.
Certified for use in Zone 1 & 2 and EMC compliant*, the IRmax is compatible with virtually any control system, requiring minimal routine maintenance helping keep costs at a minimum. The IRmax also contains no components for artificially heating optical surfaces, meaning power consumption is dramatically reduced, requiring only 1W of power.
The remote display can be mounted up to 30 metres from the IRmax and test gas can be applied without requiring direct access to the detector. It can also be wall mounted, fitted to a 50mm (2 inch) pipe or connected to an auxiliary junction box, making it a reliable and versatile choice for hydrocarbon gas detection.
Size | IRmax | 158 x 75 x 57mm (6.2 x 2.9 x 2.3ins) |
IRmax with Fixed IR display | 230 x 75 x 57mm (9 x 2.9 x 2.3ins) | |
IRmax with IS Barrier Module | 261 x 75 x 57mm (2.3 x 2.9 x 2.3ins) | |
Remote IR Display | 60 x 54 x 48mm (2.3 x 2.1 x 1.9ins) | |
Weight | IRmax | 1.58kg (3.5lbs) |
IRmax with Fixed IR Display | 2kg (4.4lbs) | |
IRmax with IS Barrier Module | 2.4kg (5.3lbs) | |
Remote IR Display | 0.2kg (0.4lbs) | |
Enclosure material | 316 stainless steel | |
Description | Dual-beam infrared hydrocarbon gas detector with optional display | |
Ingress protection | IP66 | |
Connection | One M20 or 1/2" NPT cable gland entry | |
Power | 12-30 Vdc. < 1W | |
Electrical output | 4-20mA current sink or source | |
2mA dirty optics warning (at 75% obscuration, configurable) | ||
0mA detector fault signal (at 90% obscuration, configurable) | ||
RS-485 Modbus (optional), HART 7 (optional) | ||
IR display | 4- digit LCD with back-light | |
Function buttons can be de-activated if required | ||
Terminals for connecting HART communicators (optional function) | ||
LED | Red: Gas detected | Amber: IRmax fault | Green: Healthy | |
Display functions | Gas level, obscuration level, supply voltage, signal current | |
Password protected functions | Zero, calibrate, ramp output, trim zero mA, trim span mA | |
Operating temperature | -40°C to +75°C (-40°F to 167°F) | |
Humidity | 0 to 95% RH non-condensing | |
Pressure range | Atmospheric +/- 10% | |
Repeatability | +/- 2% FSD | |
Zero drift | +/- 2% FSD per year maximum | |
Rresponse time | T90 < 4 seconds | |
Functional safety | IEC61508, EN50402 SIL2 | |
Approvals ATEX & IECEx | IRmax without Display | Ex II 2 GD Ex db IIC T6 Gb (Tamb -40°C ≤ Ta ≤ +50°C) Ex II 2 GD Ex db IIC T4 Gb (Tamb -40°C ≤ Ta ≤ +75°C) Ex II 2 GD Ex tb IIIC T135°C Db (Tamb -40°C ≤ Ta ≤ +75°C) |
IRmax with Remote and Handheld Display | Ex II 2 GD Ex db ia IIC T4 Gb (Tamb -40°C ≤ Ta ≤ +75°C) Ex II 2 GD Ex tb ia IIIC T135°C Db (Tamb -40°C ≤ Ta +40°C) |
|
IRmax with Fixed Display | EX II 2G Ex db ia IIC T4 Gb (Tamb -40°C ≤ Ta ≤ +75°C) | |
EMC Compliance | EN50270, FCC CFR47 Part 15B, ICES-003 | |
Accuracy | +/- 2% of reading | |
Linearity | +/- 3% of full-scale |