Crowcon  TXgard IS+ nitrogen dioxide, 0-10ppm top cable entry with UL approval - TIP-AL-AA-002-Z

  • Crowcon  TXgard IS+ nitrogen dioxide, 0-10ppm top cable entry with UL approval - TIP-AL-AA-002-Z
  • Crowcon  TXgard IS+ nitrogen dioxide, 0-10ppm top cable entry with UL approval - TIP-AL-AA-002-Z
  • Crowcon  TXgard IS+ nitrogen dioxide, 0-10ppm top cable entry with UL approval - TIP-AL-AA-002-Z
  • Crowcon  TXgard IS+ nitrogen dioxide, 0-10ppm top cable entry with UL approval - TIP-AL-AA-002-Z

Item #
TIP-AL-AA-002-Z
Price
$1,283.00
Quantity
Send Page to Friend

TIP-AL-AA-002-Z TXgard IS+ nitrogen dioxide, 0-10ppm top cable entry with UL approval by Crowcon

TXgard-IS+ is a Intrinsically Safe (I.S.) toxic and oxygen gas detector with local LCD display. A wide choice of sensors are available for use in a variety of applications.

Features:

Non-intrusive calibration

  • Calibration can be performed locally without the need for hot work permits
  • Local display and buttons enable calibration without opening the junction box

Flexible output options

  • A two-wire 4-20mA signal is provided
  • The output can be forced up without applying gas to enable simple checking of control systems and alarms.

Rugged and reliable

  • Constructed using highly durable GRP to provide good impact resistance
  • Ingress protection to IP65 as standard, IP66 with accessory
  • IEC61508 SIL compliant



Technical Specifications
Size
160 x 123 x 92mm
(6.3 x 4.8 x 4.5ins)
Weight
0.7kg (1.5lbs)
Enclosure material
Junction box: Carbon loaded nylon
Sensor housing: ABD Plastic
Ingress Protection
IP65
Cable entries
1 x M20 or 1/2" NPT with adaptor
Power
8-32Vdc, 4-20mA loop-powered
Operating temperatures
-20°C to +55°C (-4°F to 131°F) *
Humidity
15 to 90% RH non-condensing
Relays (optional)
N/A
Display
2-Line, 16 character LCD
Calibration method
Via push-buttons
Electrical output
2 wire 4-20mA
Terminals
Suitable for up to 2.5mm2 cable
Sensor type
Electrochemical
Repeatability
+/- 2% FSD typically
Zero drift
+/-2% FSD, 6 months typically
Response time
Contact Crowcon for a full list of sensor response times
Hazardous area zones
Zone 0, 1 or 2
Division 1 or 2
(when connected via an isolation device)
Approvals
Ex II 1 G
Exia IIC T4 Ga
UL Class I, groups A, B, C and D
EMC compliance
EN50270, FCC, ICES-003


Gases and Ranges
Gas Type
LTEL (ppm)
STEL (ppm)
Range Available
Ammonia (NH3)
25
35
50, 100, 1000ppm
Carbon monoxide (CO)
30
200
250, 500ppm
Chlorine (CL2)
-
0.5
5, 10, 20ppm
Chlorine dioxide (CLO2)
0.1
0.3
1 ppm
Hydrogen (H2)
-
-
2000ppm, 50% LEL, 100% LEL
Hydrogen cyanide (HCN)
-
10 (MEL)
25ppm
Hydrogen fluoride (HF)
1.8
3
10ppm
Hydrogen sulphide (H2S)
5
10
25, 50, 100, 200ppm
Nitrogen dioxide (NO2)
1
1
10ppm
Ozone (O3)
-
0.2
1ppm
Oxygen (O2)
-
-
25% vol.
Phosgene (COCl2)
0.02
0.06
1ppm
Phosphine (PH3)
0.1
0.2
2ppm
Sulphur Dioxide (SO2)
1
1
10, 20, 30ppm