IT-T4-11Z-ZB-2 I-Test Automated Portable Gas Detector Test Station, 1 x Gas Inlet and T4 Module for UL Regional Settings (CH4 set to 2.5%) by Crowcon
I-Test is Crowcon's newest solution to test and verify that your Gas-Pro and T4 are in a compliant state to carry out your daily work. Bump testing standards are getting tighter in all regions and the need for controlled bump and calibration records is a must. I-Test and the accompanying I-Test Manager software makes this as easy as can be.
It takes less than 1 minute to complete a bump test with I-Test
Flexible
- Mains powered, or battery back-up - Allows you to use on site, or in field
- Entirely self-contained - No extra computers or equipment required
- Ability to update Gas-Pro and T4 configurations - Update the bump test interval or alarm levels of your fleet with ease and no fleet downtime
- Data management - Archive gas level data from detectors long term
- Powerful support software - Makes configuring I-Test to site requirements extremely easy
Reliable
- I-Test recognises empty or expired cylinders - Allows for planned refills and no unit downtime
- Testing starts automatically when detector is inserted - Minimal user training required
- Ensures the audible and visual alarms are working - Gives the user full confidence that the Gas-Pro is compliant to use
- Battery backup - Testing continues even if power is out
Records
- Everything is logged - See everything that has been tested and whether it has passed/failed
- Exception reporting - Precise reports flag up who has and hasn’t carried out their bump test or calibration
- Powerful reporting - Need to see which detectors have gone in to alarm in the last month? I-Test Manager makes easy work of pulling report summaries together
Size | 110 x 250 x 320mm (4.3 x 9.8 x 12.6 ins) |
Weight | 2kg (70.5oz) |
Input Supply | 9-12V @ 3A |
I-Test backup battery | 200 speedy bump tests with 15-second intervals between tests 5 hours in standby with no bump test Battery life approximately 500 cycles Charge time 7 hours |
RTC backup battery | 3-year life |
USB interface | One standard USB type A socket for USB Flash Memory stick One standard USB type B socket for connections to PC |
Inlets/Outlets | Single gas inlet (requires demand flow regulator) Purge inlet (air) Exhaust |
Regulators | Demand flow regulator required |
Storage capacity | Internal 2GB MicroSD card |
Temperature specifications | Operating temperature: -10°C to +50°C Storage temperature: -25°C to +60°C Charging temperature: 0°C to +40°C |
Humidity | 0% and 95% relative humidity (non-condensing) at +40°C |
Ingress protection | IP20 |