Red Line Dioxide Detection Transmitter and Detector Range 0-2% CO2 v/v 4/20ma Output
General Specifications | |
Operation | continuous diffusion NDIR (dual wave-length) |
Measuring Range | 0~2% Vol CO2 |
Repeatability | ± 2% |
Warm up time to zero | < 20 seconds |
Response time to target gas | T90 < 25 seconds |
Long term zero drift | ± 25ppm CO2/ month |
Electrical Data | |
Certification | CE – C509 NOT CERTIFIED FOR USE IN A HAZARDOUS AREA |
Input Voltage | 3 wire, 12 to 35V DC (24v DC nominal - polarity protected) |
Maximum Current Consumption | 130mA |
Voltage Output | 1~5V, maximum current draw 5mA |
Resolution | 0.15% of span |
Current Output | 4~20mA (link selectable as sink or source) Maximum loop resistance in source mode is 250R |
Humidity Range | 0-99% relative humidity Non condensing |
Output Resolution | 0.02mA |
Maximum Offset drift | ± 20μA |
Over-range Output | 21.3mA (typical) |
Fault Signal | 3mA |
Fault Indicator | Open collector output switched to 0V |
Mechanical Data | |
Dimensions | 122mm x 120mm x 56mm |
Weight | 270g |
Mounting Detail | Four 4mm – 110mm vertical, 90mm horizontal |
Environmental Data | |
Ingress protection | IP64 (Water Shield fitted as standard) |
Humidity | 0 ~100% RH (non-condensing) |
Temperature | -10 to +50°C |