Crowcon UV Flame Detector (660) - Aluminium - 2060 / 1

  • Crowcon UV Flame Detector (660) - Aluminium - 2060 / 1
  • Crowcon UV Flame Detector (660) - Aluminium - 2060 / 1
  • Crowcon UV Flame Detector (660) - Aluminium - 2060 / 1
  • Crowcon UV Flame Detector (660) - Aluminium - 2060 / 1

Item #
2060-1
Price
$3,290.00
Quantity
Send Page to Friend

2060/1 UV Flame Detector (660) - Aluminium by Crowcon

The 20/20M Mini Series Flame Detectors are high performance, unique IR3 and UV/IR flame detectors featuring lower cost, lower power, and more compact structures. The mini detectors are highly resistant to harsh environments, immune to false alarms and are designed for use in OUTDOOR or INDOOR applications. The IR3 model is also available as intrinsically safe (I.S.) approved format.

The detectors' small size, low cost and low power allow easy installation in small or congested areas where Ex hazardous area approvals are not a prime requirement. Both models are packaged in rugged, stainless steel enclosures that are less than 50% of the size of our standard explosion-proof detectors and weigh only 2.5 lbs (1.2 kg).

20/20ML MINI UV/IR FLAME DETECTOR

The low cost, compact, lightweight 20/20ML UV/IR Flame Detector comprises both UV and IR sensors, detecting hydrocarbon-based fuel and gas fires, hydroxyl and hydrogen fires, as well as metal and inorganic fires at distances of up to 50 ft (15m). The UV sensor incorporates a special logic circuit that helps prevent false alarms caused by solar radiation. Simultaneous detection of radiant energy by both the UV and IR sensors triggers an alarm signal.

Main Features

  • Immune to False Alarms
  • Large Field of View (100° horizontal/vertical)
  • Low Power Consumption
  • High-Speed Response
  • Standard 4-Wire Connection
  • 4-20mA Sink or Source (3-4 wires) Configuration
  • RS-485 Modbus Compatible
  • Automatic and Manual Built-In-Test (BIT)
  • User-Programmable Function Con!gurable via software from a PC or handheld device
  • MTBF Minimum 100,000 Hours
  • 3 Year Warranty

Main Applications

  • Aircraft Hangars
  • Off road heavy duty vehicle
  • Office areas and atrium areas
  • Waste handling
  • Unmanned gas stations
  • Marine vessels engine rooms



   
20/20MI-1
20/20MI-3
20/20ML
General Specifications
Spectral Response  
Triple Spectrum Design
UV/IR Dual Sensor
   
ft (m)
ft (m)
ft (m)
Detection Range (Highest Sensitivity Setting for 1 ft2 (0.1m2) pan fire) Gasoline
133 (40)
33 (10)
50 (15)
n-Heptane
133 (40)
33 (10)
50 (15)
Diesel Fuel
90 (27)
23.1 (7)
37 (11)
JP5
100 (30)
23.1 (7)
37 (11)
Kerosene
100 (30)
23.1 (7)
37 (11)
Alcohol (Ethanol)
100 (30)
24.8 (7.5)
25 (7.5)
IPA (Isopropyl Alcohol)
100 (30)
24.8 (7.5)
25 (7.5)
Methanol
100 (30)
24.8 (7.5)
25 (7.5)
Methane*
40 (12)
10 (3)
15 (5)
LPG (Propane)*
40 (12)
10 (3)
15 (5)
Hydrogen*
---
15 (5)
Silane*
---
15 (5)
Polypropylene Pellets
16 (5)
6 (2)
15 (5)
Office Paper
50 (15)
13 (4)
12 (4)
*20" (0.5m) long 8" (0.2m) width plume fire
Response Time Typical 5 sec.
Adjustable Time Delay Up to 30 sec.
Sensitivity Range 4 Sensitivity Ranges for 1 ft2 (0.1m2) gasoline pan fire:
33 ft (10m)–133 ft (40m)
4 Sensitivity Ranges for 1 ft2 (0.1m2) gasoline pan fire:
7.5 ft (2.5m)–33 ft (10m)
1 Sensitivity Range for 1 ft2 (0.1m2) gasoline pan fire:
50 ft (15m)
Field of View 100° horizontal, 100° vertical
Built-in-Test Manual and Automatic BIT
Temperature Range Operating: -40°F (-40°C) to 160°F (70°C)
Storage: -65°F (-55°C) to 185°F (85°C)
Humidity Up to 95%
Electrical Specifications
Power Supply Operating Voltage: 18-32 VDC
Power Consumption Max. 25 mA in stand-by
Max. 50 mA in alarm
Max. 40 mA in stand-by
Max. 70 mA in alarm
Electrical Connection 12 wires 6 ft (2m) cable (for junction box connection)
Optional: 12- wires electrical connector (the suitable connector will be supplied)
Electrical Input Protection According to MIL-STD-1275B
Electromagnetic Compatibility EMI/RFI protected CE Marked
Outputs
Relays Alarm and Fault
SPST volt-free contact rates 2A at 30 VDC or 0.5A at 250 VAC Fault relay normally closed, Alarm Relay normally open
*The Relays do not apply to 20/20MI EX approved version
4-20mA
Sink (source option) configuration
Source configuration
Fault:
0 + 0.5mA
0 + 0.5mA
BIT Fault:
2mA + 10%
2mA + 10%
Normal:
5mA + 10%
4mA +5%
IR Detection:
---
8mA +5%
UV Detection:
---
12mA +5%
Warning:
10mA + 5%
16mA + 5%
Alarm:
15mA + 5%
20mA + 5%
Resistance Loop:
100-600 Ω
100-600 Ω
RS-485 The detector is equipped with an RS-485 communication link that can be used in installation with computerized controllers. The RS-485 is Modbus compatible.
Mechanical Specifications
Dimensions 4" x 4" x 2.5" (100 x 100 x 62 mm)
Weight St.St 316L 2.5lb (1.2 kg)
Tilt Mount 0.8lb (0.37 kg)
Enclosure Stainless Steel 316L with electro polish finish
Environmental standards Meets MIL-STD-810C for humidity, Salt & Fog, Vibration, Mechanical Shock, High Temp, Low Temp
Water and Dust IP66 and IP67 per EN60529
NEMA 250 6P
Approvals
Hazardous Area Ex Approvals
ATEX** 04ATEX2010
EX II 1 GD, EExia IIC T5 (60°C), T4 (85°C)
Zener barriers (not included) are required to achieve the stated approval
** The Relays do not apply to 20/20MI EX approved version
---
Functional Approvals
FM Project ID 3020071 Project ID 3013906 Project ID 3020071
VdS (EN54-10) G207073 --- ---
CPD Certificate of Conformity 0786-CPD-20916 --- ---
GOST R POCC US.HO06.B00103
Other Approvals
DNV A-12318 ---
ABS Project No. 1627964 ---
GOST K KZ.7500507.01.01.00029